Direct Connect 8 (DC8)
The Direct Connect 8 modules features 8 solid-state controlled outlets each capable of switching 120V at 6 Amps. The DC8 enables a very reliable hardwired connection between the AquaController and all controlled devices - X10 interference problems caused by noisey electronic ballasts (i.e. Blueline) are eliminated. NOTE: This module is suitable for use on ICECAP™ ballasts.

|
8 120V Outlets (Max 6 Amps, total current must be less than 15 Amps). |
Compact custom aluminum enclosure (8.8" x 3.35" x 1.6"). |
High reliability direct wired connection to the AquaController (does not use X10). |
Can be used with electronic ballasts which cause X10 interference. |
Completely Silent Operation - uses solid state relays. |
"Soft-Start" for reduced pump wear. |
Up to 5 DC8s can be daisy chained together for up to 40 switched outlets. |
All 8 outlets independently controllable. |
Control Interface (IM513) can be last device in chain (Simultaneous X10 and hardwired control) |
Fuse Protected |
4 Mounting Holes for easy installation |
Recommended for use with ICECAP™ ballasts |
|
| |
Model |
Price |
Buy |
|
| Neptune Direct Connect 8 |
146.95 |
|
Direct Connect 4 Heavy Duty (DC4HD)
The Direct Connect 4 modules features 4 relay controlled outlets each capable of switching 120V at 12 Amps. The DC4 enables a very reliable hardwired connection between the AquaController and all controlled devices - X10 interference problems caused by noisey electronic ballasts (i.e. Blueline) are eliminated. NOTE: This module is suitable for use on ICECAP™ ballasts; it utilizes large relays which can withstand the high inrush currents on these ballasts.

|
4 120V Outlets (Max 12 Amps, total current must be less than 15 Amps). |
High reliability direct wired connection to the AquaController (does not use X10). |
Can be used with electronic ballasts which cause X10 interference. |
Up to 10 DC4s can be daisy chained together for up to 40 switched outlets. |
All 4 outlets independently controllable. |
Fuse Protected |
Control Interface (IM513) can be last device in chain (Simultaneous X10 and hardwired control) |
4 Mounting Holes for easy installation. (5.8" x 4.6" x 2.4") |
Recommended for use with ICECAP™ ballasts |
|
| |
Model |
Price |
Buy |
|
Neptune Direct Connect 4HD |
122.95 |
|
Direct Connect 4 (DC4)
The Direct Connect 4 modules features 4 relay controlled outlets each capable of switching 120V at 8 Amps. The DC4 enables a very reliable hardwired connection between the AquaController and all controlled devices - X10 interference problems caused by noisey electronic ballasts (i.e. Blueline) are eliminated. NOTE: Due to the high inrush current (greater than 40 Amps) on ICECAP ballasts, we do not recommend that you use this module to control these ballasts. Use the DC4HD instead.
 |
4 120V Outlets (Max 8 Amps, total current must be less than 10 Amps). |
High reliability direct wired connection to the AquaController (does not use X10). |
Can be used with electronic ballasts which cause X10 interference. |
Up to 10 DC4s can be daisy chained together for up to 40 switched outlets. |
All 4 outlets independently controllable. |
Control Interface (IM513) can be last device in chain (Simultaneous X10 and hardwired control) |
Fuse Protected |
4 Mounting Holes for easy installation. (5.8" x 4.6" x 2.4") |
Not recommended for use with ICECAP™ ballasts |
|
| |
Model |
Price |
Buy |
|
Neptune Direct Connect 4 |
99.95 |
|
PX 1000
The first expansion module, the PX 1000 (shown above) , with a pH, ORP, temperature (or 2 pH and 1 temperature), and 6 digital inputs is available now.

|
The PX 1000 features are:
| |
Monitor/Control pH, ORP, and tempprobe or 2 pH and temp probe. |
| 6 digital inputs for float switches, water on floor sensors, pressure sensors, etc. |
| Full datalogging support in AquaController and AquaNotes. (1024 data points per measured parameter) |
| Up to 7 expansion modules can be used on the AC3 or AC3Pro. |
| Attaches to AquaController 3's I/O port with a 5' cable. |
| Additional Expansion modules daisy chain off the previous expansion module. |
|
| |
Model |
Price |
Buy |
|
PX 1000 |
170.95 |
|
|
Variable Speed Pump Module (AquaSurf)
The AquaSurf allows the AquaController to control any of the variable speed stream pumps which are compatible with the Tunze 7095 controller. Features of AquaSurf include:
Works with any of the Tunze Stream pumps that are compatible with the Tunze 7095 controller. |
4 independent channels for control of 4 pumps. |
Independent variable speed control on all channels. |
Resonate mode used to generate waves (with or without a wave box). |
Precise on/off period configuration. |
Mode of operation can be changed throughout the day. |
Uses nhanced AquaController programming language. |
Periodic pulse mode to keep fish out of the stream pump. |
Works w/ AC3, AC3Pro, and ACJr. |
2 Mounting Holes for easy installation. |
|
| |
Model |
Price |
Buy |
|
Neptune Aquasurf Tunze Controller |
170.95 |
|
|
IO Breakout Box
Easily add float switches, water on the floor sensors, etc. to the AquaController 3 or AquaController 3 Pro. Simply plug the Breakout box's minidin 8 cable into the AquaController I/O port, and then attach the float switch, or water on the float switch wires to the quick connector terminals. No soldering or special tools required.
| 5' Cable plugs into the I/O Connector of the controller. |
| Supports 2 Digital inputs on AC3. |
| Supports 4 Digital inputs on AC3Pro. |
| Supports 6 Digital inputs on PX 1000. |
| Quick Connect Terminals - no soldering required. |
2 Mounting Holes for easy installation. |
|
| |
Model |
Price |
Buy |
|
IO Breakout |
38.95 |
|
|
Socket Expansion 120V
The Socket Expansion box is a small power strip with controllable 2 outlets used to reduce the power load on a direct connect (DC) box. Since power is supplied from a different circuit, the Direct Connect box's power budget is not affected.
Dual outlets so two devices can be controlled by the same channel. |
High reliability direct wired control connection to Direct Connect outlet. |
| It can switch high power (up to 15 Amps) 120V loads. |
| The internal relay has negligible power consumption so it does not affect the power budget of the Direct Connect box |
| 2 Mounting Holes for easy installation. |
|
| |
Model |
Price |
Buy |
|
Neptune Socket Expansion |
39.95 |
|
|
Copyright©
2003-2007 Salty Critter